Sign in Register Account

Ventilator machine is one kind of our anesthesia ventilator, If this could not feed your requirement, just see other anesthesia machine, such as veterinary anesthesia machine, anesthesia ventilator, anesthesia gas machine, portable anesthesia machine.

Introduction of anesthesia machine: Do you want to know the technology of anesthesia machines?...

MSL cheap and Used ventilator machine MSLVM09 for sale, ventilator price | ventilator machine price
Product Name:  Used ventilator machine MSLVM09 for sale
Latest Price: US$100-737/Set
Model No.:  MSLVM09
Weight:  Net weight:33 Kg
Minimum Order Quantity:  1 Set Set/Sets
Supply Ability:  300 Sets per Year
Payment Terms:  T/T,L/C,D/A,D/P,Western Union,MoneyGram,PayPal
Size:  
Color:  
QTY:  

Quick Details

The ventilator is an electrically controlled pneumatic ventilator integrating such functions as time, volume cycling, pressure limit, etc. It is mainly intended for providing ventilation support to a critically ill patient during the life threatening phase. 

Packaging & Delivery

Packaging detail:Standard export package
Delivery detail:within 7-10 workdays after receipt of payment

Specifications

Used ventilator machine MSLVM09 for sale

ventilator price | ventilator machine price

Used ventilator machine VM09

 

MSL Used ventilator machine MSLVM09 for sale Main Features

The MSLVM09 ventilator is an electrically controlled pneumatic ventilator integrating such functions as time,
volume cycling, pressure limit, etc. It is mainly intended for providing ventilation support to a critically ill patient
during the life threatening phase and ensuring the going-through of the dangerous period by the patient and
smooth treatment of primary diseases for recovery. Also it provides an alternation in case of irreversible lesions
in respiratory muscles or irreversible damage to upper airway to maintain the respiratory function of the patient,
and also provides ventilation assistance for the patient during the recovery from a disease or operation. Its main
features are as follows:
A.Gas drive and electrical control, time-pressure switching and pressure limit control.
B. A high-brightness LED digital display is used to present the control frequency, tidal volume, throughput, overall
respiratory rate, spontaneous breathing frequency, etc.
C.A highly sensitive and responsive pressure sensor and a flow sensor are used to measure, control and display
the airway pressure and gas flow rate and the ventilator is equipped with automatic throughput compensation. 
D.In case of an abnormality to the ventilator or misoperation, the ventilator can raise a visual-audible alarm to
automatically protect itself. 
 
cheap ventilator machine VM09 for sale
 

Cheap ventilator machine MSLVM09 for sale Requirements for Ambient Conditions

The MSLVM09 ventilator is a mobile medical device as specified in the Environment Requirements and Test
Methods for Medical Electrical Equipment to operate in Climatic Environment Group II and Mechanical Environment
Group II. Its normal operating conditions are as follows:
——Ambient temperature: 10 ~ 40℃, relative humidity: no higher than 80%.
——Atmosphere pressure: 86kPa ~ 106kPa
——Gas source requirement: medical oxygen source with a pressure ranging from 280 to 600kPa and a flow rate
of 50L/min (containing no fresh air).
——Power supply requirements: AC 220V±10%, 50±1Hz and 30VA, well grounded. 
ventilator price | ventilator machine price
advanced Anesthesia Ventilator
 

Best ventilator machine MSLVM09 for sale Operating Principles

Driven by compressed medical oxygen, the MSLVM09 ventilator uses a gas ejector based on Venturi effect to
form a mix of medical oxygen and ambient atmosphere which is delivered through the ventilator circuit into the
airway in the patient for mechanical ventilation. During such process, a fast solenoid valve, a highly sensitive
flow sensor, a pressure sensor and a single-chip microcomputer control system are used to measure, adjust
and control such parameters as the ventilation pressure, ventilation time, throughput, etc. to the patient.
This ventilator can display in real time the following important parameters: 
——Operating mode and respiratory rate;
——Ventilator control frequency set by medical staff;
——Tidal volume of each breath in the patient;
——Occurrence of spontaneous breath in the patient and spontaneous breathing frequency;
——Expiratory phase and inspiratory phase and actual respiratory rate;
——Minute volume;
——Setting and adjustment of inspiration triggering pressure, PEEP, and highest airway pressure; 
——Real-time variation in internal airway pressure. 
This ventilator is capable of raising an alarm in case of abnormality. For example, the ventilator can
automatically alarm in case of too low airway pressure due to the gas leak in the tube or tube separation.
In case of too high tube pressure caused due to the tube blockage, it not only can raise an alarm but also
automatically switch to the expiratory phase if the pressure further rises to release the too high pressure. 
 
MSL New Anesthesia Ventilator for sale
 

Used ventilator machine MSLVM09 Technical

 

1.Basic Functions
——Sigh (deep breath);
2.Ventilation Modes
——SIPPV
——IPPV
——IMV
——SIMV
 
Technical Data
—Tidal volume range: no less than 50 to 1200ml, permissible deviation: ±20 %.
——Maximum minute ventilation: ≥ 18 L/min, permissible deviation: ±20 %.
——Oxygen concentration of output gas: <45 %.
——Controlled ventilation (IPPV) frequency range: 6 ~ 60times/min, permissible deviation: ±15 %.
——I:E ratio: 1:1.5, 1:2.0, 1:2.5 and 1:3.0, permissible deviation: ±15%.
——Maximum safety pressure: ≤6.0 KPa
——Settable maximum operating pressure: 5~6.0 KPa (gas source pressure ranging from 280kPa to 600kPa).
——Oxygen consumption: the variation in the gas pressure in the cylinder should be less than or equal to
1.5MPa/h when the ventilator operates on a 12250KPa / 40L medical oxygen cylinder continuously for one hour. 
——Inspiration triggering pressure range: -0.4 ~ 1.0 KPa, permissible deviation: ±0.15 KPa
——Time to switch between controlled and assisted ventilation modes: 6s, permissible deviation: +1 s, -2 s.
——Intermittent mandatory ventilation (IMV) frequency range: 1 to 12 times/min, permissible deviation: ±15%.
——PEEP range: no less than 0.1 to 1.0kPa. 
——Sigh (deep breath): the inspiration time should be no less than 1.5 times of the original setting. 
——Pressure limit range: 1.0~6.0kPa, permissible deviation: ±20 %
——The presentation of the spontaneous breathing frequency, overall respiratory rate and ventilation capacity is
refreshed once every minute.
——Continuous operation duration: the ventilator can operate continuously on a 24-hour basis on an AC utility main. 
——Main unit net weight: 28kg, dimension (L×W×H): 410×300×1100 (mm).
ventilator price | ventilator machine price

New Anesthesia Ventilator

 

 
Anesthesia Ventilator for sale
 
 
MSL New Anesthesia Ventilator
 

MSL New Anesthesia Ventilator for sale

Relate hot sale and cheap portable anesthesia machine

 

MSLGA07PLUS MSLPA01 MSLVM14
mechanical ventilation MSLPA01
MSLGA15 MSLVM06 MSLMN31

 

Product Inquire

Full name:*
Subject:*
Email:*
City:*
Tel:
Phone:
State:*
Message:*
  

Related Products

Connect Alwaysx

Connect us in Whatsapp or Facebook Messenger

Messenger

whatsapp