Sign in Register Account

Medsinglong other hot sale medical machine for sale

Portable Postpartum Rehabilitation Instrument MSLPR03 price | Medsinglong
Product Name:  Portable Postpartum Rehabilitation Instrument MSLPR03 price | Medsinglong
Latest Price:
Model No.:  MSLPR03
Weight:  Net weight: Kg
Minimum Order Quantity:  1 Set Set/Sets
Supply Ability:  300 Sets per Year
Payment Terms:  T/T,L/C,D/A,D/P,Western Union,MoneyGram,PayPal
Size:  
Color:  
QTY:  

Quick Details

Output pulse width:0.4ms±10%
Single pulse electricity :>7μc
Single pulse power: ≤300mJ
open-way output peak value:≤500Vp-p
Max output range value:≤40V
Output range adjustment: power output range is 0~260, increase or dis crease progressively  in proper sequence, it is steady consecutively, Min output is 2%.
Treat time:15-65 minutes,error is 1 minute.
It can bear the influence from  open circuit and  short circuit, the function is no weaken.
When output range is exceed 10 mA or 10v,the pre-set must be in min value, or else, it has no output when re-turn on the power.non-output 
Working mode: continuously 
Input:≤100VA

Packaging & Delivery

Packaging detail:Standard export package
Delivery detail:within 7-10 workdays after receipt of payment

Specifications

Specification of Portable Postpartum Rehabilitation Instrument MSLPR03:

Three-channel output,Basic Pulse wave is rectangle wave,Basic pulse frequency:800Hz±8%.
Adjusting wave and frequency:trapezoid wave 0.5-10Hz,triangle wave 1-20Hz,bell wave 0.5-10Hz (no adjusting wave below 40)
Output pulse width:0.4ms±10%
Single pulse electricity :>7μc
Single pulse power: ≤300mJ
open-way output peak value:≤500Vp-p
Max output range value:≤40V
Output range adjustment: power output range is 0~260, increase or dis crease progressively  in proper sequence, it is steady consecutively, Min output is 2%.
Treat time:15-65 minutes,error is 1 minute.
It can bear the influence from  open circuit and  short circuit, the function is no weaken.
When output range is exceed 10 mA or 10v,the pre-set must be in min value, or else, it has no output when re-turn on the power.non-output 
Working mode: continuously 
Input:≤100VA

         

Application of Portable Postpartum Rehabilitation Instrument MSLPR03:

Lactation lack at Post partum
Dredge breast
Mammitis
The recovery of the uterus
Diastasis recti abdominis
Chronic pelvic inflammation and vaginal relaxation
Retention of urine
Postoperative analgesia
Pelvic floor muscle repair
Body recovery

Product Inquire

Full name:*
Subject:*
Email:*
City:*
Tel:
Phone:
State:*
Message:*
  

Related Products

Connect Alwaysx

Connect us in Whatsapp or Facebook Messenger

Messenger

whatsapp