Patient monitor | hospital monitor MSLMP16
Function:
1.Display: 10” color TFT screen, high resolution: 800×600 dpi;
2.6 Parameters: Standard – 5-lead ECG/HR, NIBP, SPO2, Temp., Resp., PR;
Optional – 3/12-lead ECG, single/double IBP, double Temp. Sun Tech NIBP, Masimo/Nellcor Spo2, ETCO2,BIS,CO;
3.Patient Range: Suitable for Adult, Pediatric, Neonate;
4.Multi-display interface: Standard, Large font, Trend Coexist, OxyCRG dynamic,
7 Full ECG waveforms;
5.Language: Built-in 8 language for choose (English, Chinese, Turkish, Spanish, French, Russian, German, Italian);
6.Review: Maximum 720h tabular and graphic trends of all parameters, 1000NIBP records and 200 alarm event;
7.Battery: Built-in 2 hours rechargeable lithium battery, and battery volume display. 4 hours rechargeable lithium battery (optional);
8.Network: TCP/IP networking platform, connect with central monitoring system. Wifi central monitoring system (optional).
Patient monitor | hospital monitor MSLMP16
Feature:
1.Advance patient Manage: gender, full name, ID no., room no., bed no., weight, height, blood type, paced or not, remakes;
2.Multi-parameter board: Separated parameter board, main board, ECG board, SPO2 board, and NIBP board are independent;
3.Interface: Color, layout of each parameters can be set up by user need,
bed to bed view display(optional);
4.Fanless: Use special fanless cooling technology in the device to provide users quiet environment;
5.Standby: Unique standby mode for energy saving and suspend monitoring;
6.Time delay: Time delay switch-off function to save data when monitor turn off suddenly;
9.Easy software update: Users can update monitor software by themselves;
10.Analysis: Real time S-T segment analysis, and 20 type arrhythmic analysis;
SpO2 Pitch Tone Variation, Drug Dose Calculation and Hemodynamic Calculations;
11.Storage: external SD card slot enables memory extension(optional);
12.Data transfer: USB port to allow to transfer patient data to a PC (optional);
13.Special SINNOR F-6 Spo2 technology: which is as correct as Nellcor spo2 but cheaper than it(optional);
14.Resistance to interference : Efficient resistance to interference of defibrillator and HF knife;
15.Other optional: Touch Screen, Printer, Wall amount, VGA connect
Optional: Touch Screen, Printer, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, ETCO2, Sun Tech NIBP, Wall mount, VGA, Wifi
Patient monitor | hospital monitor MSLMP16
ECG
|
Lead mode: 5 –lead(R, L, F, N, C) (3/12 lead ECG for optional)
Lead selection: I, II, III, avR, avL, avF, V
Waveform: 3 and 7 channel selectable
Gain selection: 0.5mm/mv,1mm/mv,2mm/mv
Sweep speed: 6.25mm/s;12.5mm/s;25mm/s;50mm/s
Heart rate range: Adult: 15~300bpm;
Neonate/pediatric: 15~350bpm
Accuracy: +1bpm or +1%, which is greater
Resolution: 1bpm
Filter: surgery mode: 1~20Hz
Monitor model: 0.5~40Hz
Diagnostic mode: 0.05~130Hz
Scaling signal: 1mv, +3%
Protection: withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation
Alarm range: 15~350bpm
S-T segment detection:
Measurement range: 2.0mV~+2.0mV
Alarm Range: -2.0mV~ +2.0mV
Accuracy: -0.8mV ~+0.8Mv
Error: +0.02Mv
Arrhythmia analysis: YES
|
SPO2
|
Measurement range: 0~100%
Wave speed: 12.5mm/s;25mm/s
Resolution: 1%
Accuracy: +2% (70-100%); 0-69% unspecified
Alarm range 0~100%
Lower perfusion situation
|
Pulse Rate(PR)
|
Range: 20~300bpm
Resolution: 1bpm
Error: +1bpm or +2%, whichever is greater
|
NIBP
|
Method: Digital Automatic oscillometric
Operation mode : Manual/Automatic
Auto measurement time: Adjustable (1~720min) (1,2,3,4,5,10,15,30,60,90,120,240,480,720min)
Measurement Unit: mmHg/Kpa selectable
Measurement types: Systolic, Diastolic, Mean
Measurement Range:
Range of Systolic pressure: Adult: 40~270mmHg
Pediatric: 40~220mmHg
Neonate: 40~135mmHg
Range of mean pressure: Adult: 20~235mmHg
Pediatric: 20~165mmHg
Neonate: 20~110mmHg
Range of diastolic pressure: Adult: 10~215mmHg
Pediatric: 10~150mmHg
Neonate: 10~100mmHg
Over-pressure protection: Double safety protection
Resolution: 1 mmHg
Alarm: Systolic, Diastolic, and Mean
|
RESPIRATION
|
Method: RA-LL impedance
Measurement range: Adult: 7~120rpm;
Neonate/Pediatric: 7~150rpm
Apnea alarm: YES, 10~40s
Resolution: 1rpm
Accuracy: +2rpm
|
TEMPERATURE
|
Compatible probe: YSI or CYF
Measurement range: 5~50℃
Resolution: 0.1℃
Accuracy: +0.1℃
Refreshing time: about 1
Average measuring time: <10s
|
Accessories supplies
1. 5 lead ECG cable 1set
2. Adult Spo2 probe 1set
3. Adult NIBP Cuff and extension tube 1set
4. Temp probe 1set
5. Ground connecting liner 1set
6. ECG Chest electrode (10pcs/pack) 1pack
7.2200mA lithium battery 1PCS
MSL TEAM picture


MSL Certificate
MSL Medical cooperate with DHL,FEDEX,UPS,EMS,TNT,etc.International shipping company,make your goods arrive destination safely and quickly.