Product Specifications - HX10 20KW High Frequency X-ray Machine (Analogue Radiography System)
This professional 20KW medical X-ray system is a high-performance high frequency X-ray machine engineered for clinical full-body radiography, featuring strong penetration, intelligent control and flexible operation. As the flagship HX10 high frequency X-ray machine, it meets the diverse radiographic needs of medical institutions with reliable and stable performance. Below are its complete technical specifications:

Generator Specifications
- Input Power: 220VAC, Single phase, ±10% 50/60Hz
- Nominal Electric Power: 20KWThe high power output makes this 20KW medical X-ray system ideal for high-demand clinical imaging, including obese patient examinations.
- Tube Current (mA): 10-200mA
- Tube Voltage: 40kV-150kV, 1kV stepThis 40-150kV digital radiography machine offers precise voltage adjustment for different body part imaging needs.
- Current Time Product (mAs): 0.1-100mAs
- Loading Time (ms): 1-6300ms
- Inverter Frequency: 40kHz ±5%Stable high-frequency inversion ensures consistent energy output for clear radiographic results.

X-ray Tube Specifications
- Focal Spot: 0.5mm/1.0mmDual focal spot sizes support both high-resolution and large-field imaging for comprehensive full-body radiography X-ray unit applications.
- Focal Power: 10kW/33kW
- Tube Voltage Range: 40KV-125KV
- Anode Heat Capacity: 100kJ (140kHU)Large heat capacity enables continuous clinical operation without frequent downtime.
- Anode Target Angle: 16°
- Rotary Anode: 2800rpmHigh-speed rotary anode ensures uniform heat distribution and extended tube service life.

Collimator Specifications
- Power Supply: ACDC 24V±10%
- Field Light: LED, 5W
- Collimator Rotation Range: 360° any angleFull-angle rotation meets flexible positioning needs for different radiographic postures.
- Min. Brightness: 160Lux
- Maximum Field Size: 430mm×430mm at SID=100cm
- Light Timer: 30±2s

Radiographic Table Specifications
- Type: Fixed Checking 4 directional floating table (Mobile Type)The mobile and floating design optimizes patient positioning for the HX10 high frequency X-ray machine.
- Table Size: 2100×650mm×750mm
- Table Longitudinal Movement: 1100mm
- Bucky Size: 17×17inch
- Tube Rotation Angle Range: Manual 90°
- Column Moves Up and Down: Manual

Bucky Stand Specifications
- Tube Vertical Movement Range: 1400mm
- Control Mode: Manual
- Height: ≤2250mm
- Lifting Stroke: 1400mm, ±5%
- Size of Wall Stand Tray: 17×17inch


Core Functional Features
- Full-body Radiography Capability: Adapts to head, chest, abdomen, waist, thorax, pelvis, limbs and other body parts; supports lay decubitus, normotopia, side position and other postures.
- DR Upgrade Reserve Interface: Rich expansion ports for future digital radiography upgrade, a key advantage of this DR upgradeable X-ray equipment.
- Fault Self-diagnosis and Protection: Real-time fault detection and automatic protection ensure safe and stable operation.
- Automatic Calibration of Tube Current: Maintains imaging consistency and reduces manual adjustment work.
- Filament Dormancy Function: Saves energy and extends the service life of the X-ray tube.
- Analog-digital Double-loop Control: The analog-digital double-loop X-ray machine features simple operation and high intelligence, suitable for different medical staff operation levels.
- Strong Penetration: High kV, high current and high power design can handle obese patient imaging needs effectively.