300ma x-ray machine
can used for general radiography, Bucky radiography of body's head, chest, foot and hand, bones in lying.
300ma xray equipment/xray machines-MSLCX14
General radiography,Filter-ray-filter radiograph;Unit Configuration Control ,HT generator unit,Ht cable,X-ray tube unit,Radiographic table-X-ray source column ,Collimator Function.
The unit can used for general radiography, Bucky radiography of body’s head, chest, foot and hand, bones
in lying.

xray machines
Feature
1. meter-indicating
2. single-table single tube
3. single-phase, full wave rectification
4. stationary anode x-ray tube assembly
5. X-ray tube filament s voltage regulator, space charge compensator
6. Radiograph plain table wimple structure and easy assembling
MAIN TECHNICAL INDEXES
ITEM
|
CONTENTS
|
INDEX
|
Demand of power supply
|
Capacity
|
Two-phase 30KVA
|
Voltage Frequency
|
380V/220V ±10%50HZ ±0.5Hz
|
Intemal resistance
|
0.75Ω(380V)0.25Ω(220V)
|
power supply
|
Adjustable range
|
380±10% at220V being adjustable continuously
|
Radiograph
|
Voltage
|
50-125KV being adjustable continuously
|
current
|
Small focus:50mA100mA, Big focus:50mA 100mA 200mA 300mA
|
time
|
0.04~6.35s 23grades together grading a according to R10 coefficient
|
High-voltage generator
|
Capacity
|
20KVA(instantaneous)
|
Max DC output voltage
|
125KV
|
Max DC output current
|
300mA
|
X-Ray tube
|
Model
|
XD51.20-40/125
|
Focus
|
Small focus 1×1mm big focus2×2mm
|
Radiographic table
|
Length*width*height of bed surface
|
2000mm×665mm×700mm
|
Moving range of bed surface
|
640mm in Length, 200mmin breadth
|
Ray-filter of table
|
Travel in length ≥500mm
|
Grid density N=28
|
Convergence distance f.=100cm
|
Grid ratio r=8
|
Column of X-ray tube unit
|
Moving Longitudinally along Radiographic table
|
1000mm or 1800mm
|
Distance to friend as moving up and down (along column)
|
650~1800mm
|
Rotary around the center of cross arm
|
±180°
|
Rotary around the shaft line of X-ray annular tubes
|
-10°~60°~ +120°
|
Max size of cassette
|
356mm×432mm(14×17)
|
X-ray accessories:

Full body radiation protective suit | Radiation proof suit - MSLLS01

X-ray lead gloves | Nuclear gloves - MSLRS04

Lead leg pads | X ray foot guard - MSLRS02

Cheap X-ray lead glasses for sale - MSLLG02

Hospital or medical rubber sheet - MSLLR01

4 Casters X-ray lead screen - MSLLD02

Discount Medical x-ray film with CE for sale - MSLMF01

Developing solution | Film developing liquid - MSLDS01

Green sensitive x ray film with CE for sale - MSLMF02

X ray lead glass | X ray protection glass - MSLLG01

Lead free apron | x-ray protection clothing - MSLLA01

X-ray intensifying screen - MSLMF04

X ray lead protective aprons-MSLLA04

Lead foil sheet or rolled lead sheet - MSLLS02

X-ray film cassette - MSLMF03