Sign in Register Account

MSL A CT scan has many uses, but is particularly well-suited to quickly examine people who may have internal injuries from car accidents or other types of trauma. A CT scan can be used to visualize nearly all parts of the body and is used to diagnose disease or injury as well as to plan medical, surgical or radiation treatment.

Best Precision 32 Computed Tomograph System MSLCTX10
Product Name:  MSLCTX10 CT Scan Machine - 0.275mm Ultra-thin Imaging & 32-Slice Dual Energy
Latest Price:
Model No.:  MSLCTX10
Weight:  Net weight: Kg
Minimum Order Quantity:  1 Set Set/Sets
Supply Ability:  300 Sets per Year
Payment Terms:  T/T,L/C,D/A,D/P,Western Union,MoneyGram,PayPal
Size:  
Color:  
QTY:  

Quick Details

MEDSINGLONG MSLCT10 pet scan machine offers 4-in-1 CT/DR/fluoroscopy/panoramic imaging. With 4.5s ultra-fast scanning, ultra-low radiation, and 80cm large bore, it’s ideal for head, spine, tumor & more animal diagnostics. One-click triple-phase imaging ensures precise results. A top veterinary imaging solution.

Packaging & Delivery

Packaging detail:Standard export package
Delivery detail:within 7-10 workdays after receipt of payment

Specifications

Features of Precision 32 Computed Tomograph System MSLCTX10:

MSLCTX10 CT system is completely developed by Campo Imaging. It is the first CT product of Campo Image. P-Axial is a patent of MSLXTX10 CT system. It can obtain the thinnest CT images in the 0.275mm and has obvious advantages in the application of inner ear imaging and pulmonary nodule detection. 32-slice dual energy imaging extended the application of CT dual energy imaging. MSLXTX10 CT system provides high quality images and stable performance which can help hospitals to achieve comprehensive accurate diagnosis, and it will redefine the new standards of 32-slice CT imaging.

AccuScan-Enjoy ease
Space saving and cost saving in maintennace
Ahead-Head dual-energy head imaging technology
AccuTilt dual-mode gantry tilt technology
AccuOrgan-Targeted organ imaging
Admir iterative reconstruction technology
AccuDose-Comprehensive low dose imaging

Specification of Precision 32 Computed Tomograph System MSLCTX10:

Slip ring  Germany low-voltage slip ring
Aperture Size  715±5mm
Tilt Angulation Range  -30° ~ +30°
Scan localizer  Positioning laser
Slice Thickness  2x1.1mm 8x0.55mm 16x0.55mm 16x1.1mm
Scan time (s/360°)  0.72s, 0.8s, 1.0s, 1.5s, 2.0s
Maximum FOV (Field of View) 500mm
Detector Type  GOS ceramic solid detector
Detector Number  888x24
Detector Row  24
Detector channel per row  888
X-ray Tube

Parameter Scan room Operation room
Temperature +18℃~+24℃ +10℃~+40℃
Relative humidity 30%~60%(no condensing) 30%~75%(no condensing)
Air pressure 70kPa~106kPa 70kPa~106kPa

Tube Type  Varex GS-30719
Focal Spot Size  0.7x0.8; 1.2x1.4
Cooling Method  Oil
Heat Storage Capacity  3.5 MHU
Maximum Anode Cooling Rate 8750W (12250 HU/sec)
Maximum Continuous Anode Heat Dissipation 3400W (4760HU/sec)
High Voltage Generator

HVG Type  Spellman CT70PN42X5245
Maximum Power  42kW
Output Voltage  60kV, 70kV, 80kV, 100kV, 120kV, 140kV
Output Current  10mA ~ 350mA
Maximum  Continuous Exposure Time 100s
Patient Couch

Parameter Condition
Voltage 380VAC±10%;
Frequency 50Hz±1Hz;
Power ≥55KVA;

Movement Range  0 ~ 1725mm
Maximum Scan Range  1650mm
Horizontal Speed Range  0.5 ~ 300mm/s
Vertical Range  450mm ~ 920mm
Maximum Load Capacity  205kg
Console (Minimum Configuration Requirement)

Specifications
S/N Item Specifications
1 Gantry
1.1 Slip Ring Low-voltage slip ring
*1.2 Aperture Size 715mm
1.3 Tiltangulation Range ±30° 1.4 Laser Positioning System
Provided, provide sagittal, coronal and
internal and external cross-sectional
positioning lines
1.5 Scanning Collimation
2x1.1mm;8x0.55mm;16x0.55mm;16x1.1m
m
1.6 Sampling Rate 1800 view/ cycle
1.7 Min Scan Time (s/360°) 0.72s
1.8 Max FOV (Field of View) 500mm
1.9 Data Transmission Mode Digital transmission
1.10 Cooling-down Method Air cooling heat dissipation
2 Detector
2.1 Detector Type GOS ceramic solid detector
2.2 Detector Number 888x24
2.3 Detector Row 24
2.4 Detector Channel Per Row 888
*2.5 Detector Thickness Per Row 0.55mm

CPU  3.5GHz
Hard Drive  3TB
Host Memory  16GB
Image Storage  500GB
Graphics  3G
Display Monitor  LCD 23’ LCD 1920x1080 Resolution
Archive  DVDRW
UPS for console  Configuration
Axial Scan

Scan FOV  500mm
Slice Thickness  8×0.55mm, 16×0.55mm, 16×1.1mm
Image Thickness  0.55mm, 1.1mm, 2.2mm, 4.4mm, 8.8mm
Recon FOV  ≥50mm and ≤500mm
Recon Matrix  512×512, 768×768, 1024×1024
Helical Scan

3 X-ray System
*3.1 Focal Point Bifocus
3.2 Focal Spot Size 0.7mmx0.8mm; 1.2mmx1.4mm
*3.3 Heat Storage Capacity 3.5 MHu
3.4 Max Anode Cooling Rate 8750W (12250 HU/sec)
3.5 Tube Life 100000 second exposure
3.6 Max Output of Tube Voltage 140kV
*3.7 Min Output of Tube Voltage 60kV
3.8 Output Voltage 60kV, 70kV, 80kV, 100kV, 120kV, 140kV
3.9 Max Output of Tube Current 350mA
*3.10 Min Output of Tube Current 10mA
*3.11 Max Power 42kW
3.12 Max Continuous Exposure Time 100s
4 Scanner Table
4.1 Horizontal Movement Range 0 ~ 1725mm
4.2 Max Scan Range 1650mm
*4.3 Max Horizontal Speed Range 300mm/s
4.4 Repetitive Positioning Accuracy ±0.25mm
4.5 Min Vertical Range 450mm
4.6 Vertical Lift Range 470mm
*4.7 Max Load Capacity 205kg

 

Slice Thickness  8×0.55mm, 16×0.55mm, 16×1.1mm
Pitch  0.51:1~1.5:1
Image Thickness  0.55mm, 0.8mm, 1.0mm, 1.5mm, 2.0mm,
3.0mm, 4.0mm, 5.0mm, 8.0mm
Max.  Continuous  scan length 1650mm
Max. Continuous scan time  100s
Recon FOV  ≥50mm and ≤500mm
Recon Matrix  512×512, 768×768, 1024×1024

5 Scanning and image reconstruction system
5.1 Scan Mode
Tomoscan,Helical Scan, Precision Tomoscan, Dual Energy Scan(Optional )
*5.2 Min Image Thickness 0.275mm
*5.3 Recon Matrix 512×512,768×768, 1024×1024
*5.4 Max Recon Matrix 1024×1024
5.5 Max Continuous Scan Length 1650mm
5.6 Max Scan Field of View 500mm
5.7 Max Recon Field of View 500mm
5.8 Min Recon Field of View 50mm
5.9 Spatial Resolution
16.6LP/cm@MTF10%
21LP/cm@MTF0%
5.10 Low Density Resolution 4.0mm@0.3%
5.11 CT Value Display Range ±16383
5.12 Display Gray Scale 256, 24bit color
5.13
Thin-layer Scanning of Different
Thick Layers Reconstruction
Function
Provided
5.14 Iterative Reconstruction
Provided, P-IR dual-domain iterative
de-noising reconstruction technology, real image, no wax symbol

Client Usage Photos of Precision 32 Computed Tomograph System MSLCTX10
Please contact us for more details.

 

Product Inquire

Full name:*
Subject:*
Email:*
City:*
Tel:
Phone:
State:*
Message:*
  

Related Products

Connect Alwaysx

Connect us in Whatsapp or Facebook Messenger

Messenger

whatsapp